Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
Search Results "Door Clear Width"
-
11B-408.3.2.1 Power operation
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
611.2 Clear Floor Space
A clear floor or ground space complying with 305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space for forward approaches must extend up to or, if knee or toe space is provided, below operable parts....
-
602.2 Clear Floor Space
602.2 Clear Floor Space. Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. ...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. ...
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
1009.2.3 Clear Deck Space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
203.9 Employee Work Areas
Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with...
-
203.9 Employee Work Areas
203.9 Employee Work Areas. Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so...
-
D4. Door Clearance
On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?...