5.8.2.6 Clearance Depth at Toe Height Above the Ground. The toe clearance depth should be 22 inches minimum at toe height....
Search Results "Character Height (Visual)"
Commonly Searched Documents
-
5.8.2.6 Clearance Depth at Toe Height Above the Ground
-
2. Analysis of footrest clearance height and depth
Analysis of footrest clearance height and depth Any base support or flange for the mammography machine at floor level (inside the clear floor space width) would obstruct some wheelchair...
-
M305.2.2.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M305.2.2.1 shall be 15 inches (380 mm) long minimum. Transfer supports shall be positioned along 13 ½ inches...
-
M305.2.4.1 Circular Cross Section
Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
Typical Transfer Techniques: Staff Assistance and Patient Lifts
Typical Transfer Techniques: Staff Assistance and Patient Lifts Some individuals will need additional assistance to get on and off an exam table, even if it lowers to 17‒19 inches...
-
M305.2.1 Location (Section-by-Section Analysis)
The MDE NPRM proposed that transfer supports be located within reach of the transfer surface and not obstruct transfer onto or off of the surface when in position (proposed...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
11B-411.2.1.7.1 Assignment by keypad hall call console
The display screen shall indicate the elevator assignment characters and a verbal announcement shall be made of the assigned elevator responding to the call....
-
5.4.3.1 Positioning Support Height for Imaging Equipment
5.4.3.1 Positioning Support Height for Imaging Equipment. Positioning supports should be positioned 3 to 6 inches above the transfer surface....
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
- 2101KG HR Digital Platform Scale with Mechanical Height Rod
- 2101KL HR Digital Platform Scale with Mechanical Height Rod
-
Non-Tactile Signage
Non-Tactile Signage The legibility of printed characters is a function of the viewing distance, character height and proportion, font, and the color contrast between character and background...
-
5.8.2.1 Height of Breast Platform At Time of Measurement
5.8.2.1 Height of Breast Platform At Time of Measurement. All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor....
-
Visual Detection of Detectable Warning Materials by Pedestrians with Visual Impairments - Final Report
(Task Order 18 under Project DTFH61-01-C-00049) Authors: James Jenness & Jeremiah Singer May 24, 2006 Prepared for: Federal Highway Administration Washington,...
-
Emergency Communications [4.10.14]
An audio system with a visual display can provide information on the status of a rescue....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
February 8, 2012 UNITED STATES ACCESS BOARD A FEDERAL AGENCY COMMITTED TO ACCESSIBLE DESIGN 1331 F Street, N.W. Suite 1000 • Washington, D.C. 20004‒1111 (800) 872‒2253...