Advisory information recommends additional maneuvering clearance at turns or changes in direction, recesses and alcoves, building entrances, and along curved or angled routes, particularly...
Search Results "Bedside Clearance"
Commonly Searched Documents
-
Continuous Width (R302.3) (Section-by-Section Analysis)
-
Questions Posed in the NPRM Regarding Costs and Benefits of Complying With the 2010 Standards (Section-by-Section Analysis)
., side reach, water closet clearances in single-user toilet rooms with in-swinging doors, stairs, elevators, location of accessible routes to stages, accessible attorney areas and witness...
-
Clear Floor Space [4.16.2]
amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor space at other provided fixtures, door swing and maneuvering clearance...
-
Non-Tactile Signage
contrast · non-glare finish · light/dark contrast · non-glare finish Location · 60" height to centerline on wall at latch side of doors · 80" min. vertical clearance...
-
Mounting Location and Height [4.30.6]
The wheelchair maneuvering clearance required on the pull side of doors should allow adequate space....
-
Car Controls [4.10.12]
elevator code; where they are provided, they must be grouped at the bottom of the panel no lower than 35 inches from the floor Recommendation: consider a minimum 3/16 inch vertical clearance...
-
3.3.13 360-Degree Turn
In the UDI sample, at least one power wheelchair user required a much larger clearance for the 360-degree turn (most likely the person with the “trailer” mentioned previously)....
-
RECOMMENDATIONS
Provide a minimum 24" clearance between any obstruction (e.g., sidewall) and the side of the toilet seat....
-
Identification [§216.5, §502.6]
Signs can be on posts, or where feasible, on walls or suspended from ceilings (an 80” minimum headroom clearance is required at signs suspended above circulation paths (§307.4))....
-
Questions Posed in the NPRM Regarding Costs and Benefits of Complying With the 2010 Standards (Section-by-Section Analysis)
., side reach, water closet clearances in single-user toilet rooms with in-swinging doors, stairs, elevators, location of accessible routes to stages, accessible attorney areas and witness...
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
A lavatory with knee space can overlap the clear floor space required for the water closet provided that at least 36 inches of clearance is maintained between the side wall next to the water...
-
A) Accessible Parking
requirements as accessible parking spaces for cars and have three additional features for vans: • a wider access aisle (96 inch-wide) to accommodate a wheelchair lift; • vertical clearance...
-
References
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. 405.4 Floor or Ground Surfaces....
- DORMA ED700 Low-Energy Swing Door Operator
- Bradley 3-Station Frequency Lavatory System FL-3H & FL-3L
- Supergrit Safety Treads
-
EXECUTIVE SUMMARY
Signal Clearance Intervals Roadway users approaching a traffic signal that changes to yellow often cannot stop before the signal turns red; signal clearance intervals allow time to enter...
-
Accessible Parking
wheelchair user to exit her car, she must place her wheelchair in the access aisle, transfer from the car seat to her wheelchair, and then roll backward in the access aisle to provide clearance...
-
Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Weight Scales
Technical Criteria Types Of Equipment To Which Technical Criteria Applies Seated in a wheelchair (M303) Wheelchair space, including orientation, width, depth, knee and toe clearance...
-
R204.4 Pedestrian Overpasses and Underpasses
Long ramps present difficulties for some pedestrians with disabilities and can require snow clearance. Elevators or lifts can require maintenance....
-
New Construction
Designers should use the Chapter 3 building blocks that address reach ranges, knee and toe clearance, clear floor space, protruding objects and operable parts when designing the space....
-
Automated Revolving Doors
Other recommendations from this study include: a minimum 32 inch clearance for each leaf when hinged out for emergency use safety systems such as motion detectors within...
-
Other relevant federal rules and guidance documents
The FDA-CDRH may develop a guidance document to inform manufacturers how it intends to apply its regulatory authority to clearance or approval of medical devices addressed in the Access...
-
Ground Level Play Components: ADA Standard Section 240.2.1
Section 240.2.1 covers scoping requirements in the current ADA Standards for ground level play components.