Where provided in common use and public use areas that serve picnic units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature...
Search Results "Single-Story Dwelling Unit (FHA)"
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
-
809.2.6 Weather Alert Systems
809.2.6 Weather Alert Systems Where weather alert systems are provided in emergency transportable housing units, this section requires the operable parts on weather alert systems in units...
-
Guidelines for Requirement 2
To require such application in individual dwelling units would exceed the requirements imposed by the Fair Housing Act....
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
This section contains the scoping requirements for outdoor constructed features provided in common use and public use areas that serve camping units with mobility features....
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
This section contains the scoping requirements for outdoor constructed features provided in common use and public use areas that serve picnic units with mobility features....
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The...
-
1134A.8, Item 7
7. Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed...
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5...
-
3.1.4.1 Width of Non-RV Campsite Vehicle Parking Areas
Where a double camping unit is provided and two parking areas are provided to accommodate two vehicles side-by-side in an accessible parking spur, the total width of the vehicle parking...
-
Width of Spaces [1012.3]
Parking spaces within camping units with mobility features do not have to be striped or identified by the International Symbol of Accessibility....
-
4(2)(a)
(a) In single-story dwelling units with lofts, all spaces other than the loft are on an accessible route....
-
1.1.7.3.1 Detached one- and two-family dwellings
Detached one- and two-family dwellings, lodging houses, live/work units, townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory...
-
3.1.4.2 Width of RV Campsite and Dump Station Vehicle Parking Areas
Where RV camping units or dump stations are provided, vehicle parking areas for recreational vehicles and trailers that are required to be accessible in accordance with table 3.1.1 shall...
-
F245.4.2 Routes to and Within Common Use and Public Use Areas
Common use and public use areas serving picnic units with mobility features shall provide outdoor recreation access routes in accordance with F245.4.2....