The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
Search Results "Pull Side"
Commonly Searched Documents
-
1132A.5.1 General
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
MINIMUM MANEUVERING CLEARANCE Approach direction Perpendicular to doorway Parallel to doorway (beyond stop/latch side...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. [2010 ADAS] Advisory 221.2.3.1 Horizontal Dispersion. ...
-
11B-221.2.3.1 Horizontal dispersion
In row seating, two wheelchair spaces shall be permitted to be located side-by-side. Advisory 11B-221.2.3.1 Horizontal dispersion....
-
Station Names: ADA Standard Section 810.6.3
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-806.2.3.1 Personal lift device floor space
The clear space shall extend under the bed parallel to the long side and be adjacent to an accessible route....
-
11B-605.4 Flush controls
Urinals provided in urinal compartments and with hand operated flush controls shall have the controls located on the open side of the urinal....
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2)....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
604.5.2 Rear Wall
The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide....
-
Scoping [4.1.3(20)]
Specifications in 4.34.2 and 4.34.3 were modified in June 1993 to allow either a forward or side approach and to provide further guidance on side reach heights....
-
5.3.4 Grab Bars
In such cases, the riser shall have vertical or nearly vertical sides and a flat area on each side of the seat that is about 3 inches (75 millimeters) wide. ...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Spy City Café
The force required to push or pull open the interior hinged vestibule doors to the men's and women's toilet rooms designated as accessible is 10 pounds of force (lbf), which exceeds the...
-
11B-206.4.10 Medical care and long-term care facilities
interpretation of Subsection 11B-206.4.10: Section 11B-206.4.10 requires a minimum of one accessible entrance to be provided with weather protection, passenger loading zone, and vehicle pull-up...
-
1009.5.2 Transfer Space
by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall be centered along a 24 inch (610 mm) minimum side...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....