Each transfer step shall be 8 inches (203 mm) high maximum.
Search Results "Handrail Height"
-
11B-1008.3.2.2 Height
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
ETA Editor's Note Sections from California Building Code Chapter 4 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To see...
-
f-iv
At least 36 inches between handrails 2. Top landing part of walk 3. Bottom landing part of walk 4. Handrail height 34 to 38 inches 5. Edge protection....
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
M305.1 General
Supports shall comply with M305.
-
M305.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Accessible Medical Equipment
Importance of Accessible Examination Tables, Chairs and Weight Scales http://www.hfcdihp.org/products Exam Room Selection for Accessible Examination Tables & Chairs PDF...
-
M305.1 General
Supports shall comply with M305, as applicable.
-
Attachment H: Modifications to Altered Facilities
Attachment H: Modifications to Altered Facilities
- American Standard Cadet 1.1 gpf FloWise Right Height Pressure Assisted Elongated Toilet 2467100
-
Amusement Rides
Word Fillable Form (0.8MB) Word Non-Fillable Form (0.7MB) PDF Non-Fillable Form (0.5MB)
- American Standard Yorkville 1.1 gpf FloWise Right Height Elongated Pressure Assisted Toilet
- Spectrum Industries Inc. Freedom XRS Elite Lectern™ Adjustable Height Lecterns
-
Polling places that cannot be remediated with temporary measures:
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height. 3....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height....
- American Standard Right Width 1.28-1.6 gpf FloWise Right Height Elongated Flushometer Toilet
-
M303.3.3 Ramped (Section-by-Section Analysis)
The commenter, a medical association, concurred with the requirement for handrails on diagnostic equipment with ramps over six inches in height....
-
11B-405.5 Clear width
Handrails may project into the required clear width of the ramp at each side 3½ inches (89 mm) maximum at the handrail height. 3. ...
- Guide for Home Remodeling for People with Disabilities and Special Needs: What You Need to Know