Travel Indoor navigation provides travelers at airports, railway-stations, etc. with mobile assistance; for example guiding them to the right place – specific gates, VIP lounges, information...
Search Results "Direction of Travel"
- indoo.rs® Indoor Navigation Solution App
-
1118B.4
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 inch (12.7 mm) wide in one direction (see Figure 11B-7E)....
-
11. Fixing my business will be too expensive; therefore, I am unable to do anything to reduce my risk.
The claim must be based on one or more of the following technical violations: 1) Interior signs, other than directional signs or signs that identify the location of accessible elements,...
-
May employers subject employees to periodic alcohol testing?
Employers, however, may subject employees who have been in alcohol rehabilitation programs to periodic alcohol testing where the employer has a reasonable belief that the employee will pose a direct...
-
Maneuvering Space
A 60-inch (1525 mm) turning circle permits individuals with mobility devices to turn around A 60-inch (1525 mm) T-Shaped turn allows an individual to change directions by making...
-
Department of Justice method
The directions for using a level are as follows. "Using a builders level, place the level on the pavement at the steepest point parallel to the direction of the slope....
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
ASSISTIVE LISTENING SYSTEM (ALS)
system utilizing transmitters, receivers, and coupling devices to bypass the acoustical space between a sound source and a listener by means of induction loop, radio frequency, infrared, or direct-wired...
-
Areas of Refuge (Preamble, Section-by-Section Analysis)
- Areas of refuge (areas with direct access to a stairway, and where people who cannot use stairs may await assistance during a emergency evacuation) will be required, as proposed, but the...
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction....
-
1016.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
T603.3.2 Non-Rail Vehicles with Gross Vehicle Weight Rating Less than 30,000 lbs
On non-rail vehicles with a gross vehicle weight rating less than 30,000 pounds (13,608 kg), wheelchair securement systems shall restrain a force in the forward longitudinal direction of...
-
R. Program Access
"Program Access" means applicable Accessibility Laws directing a public entity to operate each service, program, or activity so that the service, program, or activity, when viewed in its...
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
4.26.3(4)
(4) Tensile force induced in a fastener by a direct tension force of 250 lbf (1112N) plus the maximum moment from the application of 250 lbf (1112N) shall be less than the allowable withdrawal...
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction....
-
1016.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
Can handrails overlap ramp landings?
This also applies to landings required to be at least 60” by 60” where ramps change directions so that the minimum landing area remains clear....
-
1.1.15 Flatness of ramp landings
Measure ramp landings at the midpoints of each landing in each direction using a 24 - in (600 mm) digital inclinometer....
-
Areas of Refuge (Section-By-Section Analysis and Response to Comments)
- Areas of refuge (areas with direct access to a stairway, and where people who cannot use stairs may await assistance during a emergency evacuation) will be required, as proposed, but the...
-
1134A.6, Item 2
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
ACCESSIBILITY FUNCTION BUTTON
destination-oriented elevator system that when pressed will activate a series of visual and verbal prompts and announcements providing instruction regarding hall call console operation and direction...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....