Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
Search Results "Transfer Seat (Amusement)"
-
5.1.5 Floor Height
-
11B-206.2.4 Spaces and elements
In assembly areas with fixed seating required to comply with Section 11B-221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an...
-
11B-206.2.4 Spaces and elements
In assembly areas with fixed seating required to comply with Section 11B-221, an accessible route shall not be required to serve fixed seating where wheelchair spaces required to be on an...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
- Kompan, Inc. M582 - PlayWorks Sand Play Structure
-
Bradley 2-Stall Seat Cover/Tissue Dispenser 5921 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley 1-Stall Seat Cover/Tissue Dispenser 5922 Plan
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Needs Photos or Technical Info
This article is a good start but, really could use some photos to illustrate the text. For example, what is a faucet that is placed out of reach for persons with cognitive...
-
§ 36.302(f)(2) Availability
Tickets for accessible seating shall be made available during all stages of ticket sales, including, but not limited to, presales, promotions, lotteries, waitlists, and general sales....
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the...
-
CHAPTER 9: BUILT-IN ELEMENTS
[See subsections ...]
-
DIVISION 9: BUILT-IN ELEMENTS
[See subsections ...]
-
DIVISION 9: BUILT-IN ELEMENTS
[See subsections ...]
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the...
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the...
-
221.2.2 Integration
Wheelchair spaces shall be an integral part of the seating plan. 36.308 Seating in Assembly Areas....
-
M303.4.1 Breast Platforms
The height of the breast platform shall be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when in use by a patient seated in a wheelchair....
-
§ 38.75(b)
(b) Where designated wheelchair or mobility aid seating locations are provided, signs shall indicate the location and advise other passengers of the need to permit wheelchair and mobility...
-
221.2.2 Integration
The requirement that wheelchair spaces be an "integral part of the seating plan" means that wheelchair spaces must be placed within the footprint of the seating area....
-
F221.2.2 Integration
The requirement that wheelchair spaces be an "integral part of the seating plan" means that wheelchair spaces must be placed within the footprint of the seating area....
-
Height of Tables or Counters [4.32.4]
Height of Tables or Counters [4.32.4] Counter and table surface heights (28 to 34 inches) should be specified in consideration of the intended use. A height at the lower end of...
-
4.32.4* Height of Tables or Counters
The tops of accessible tables and counters shall be from 28 in to 34 in (710 mm to 865 mm) above the finish floor or ground.