Where the diagnostic equipment is used in a reclined position, head and back support shall be provided and shall comply with M305.5.
Search Results "Critical Care Patient Room"
-
M302.3.3 Head and Back Support
-
M302.2.4 Transfer Sides
Options to transfer from a mobility device shall be provided on two adjoining sides of transfer surfaces. EXCEPTION: Options to transfer to or from a mobility device onto...
-
M305.3.3 Fittings (Section-by-Section Analysis)
The MDE NPRM proposed to prohibit standing supports from rotating in their fittings. There were no comments on this section and it was not addressed by the MDE Advisory Committee....
-
M303.2 Wheelchair spaces (Section-by-Section Analysis)
This is an introductory section.
-
5.3.3 Transfer Sides Recommendations for M302
5.3.3 Transfer Sides Recommendations for M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be located to provide...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface.
-
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests
5.3.3.1 Transfer Sides for Exam Chairs with Fixed Footrests. The 17 inch minimum depth and 21 inch minimum width should be located on both sides of examination chairs with a fixed...
-
M302.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
M303.2.3 Depth
Where wheelchair spaces can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where wheelchair spaces can be entered only from the...
-
M302.3.3 Head and Back Support
Where the diagnostic equipment is used in a reclined position, head and back support shall be provided. Where the incline of the back support can be modified while in use, head and...
-
M303.2.2 Width
Wheelchair spaces shall be 36 inches (915 mm) wide minimum.
-
M305.3.3 Fittings
Standing supports shall not rotate within their fittings.
-
806.1 General
Transient lodging guest rooms shall comply with 806. Guest rooms required to provide mobility features shall comply with 806.2....
-
9.2.2(8)
(8) Sleeping room accommodations for persons with hearing impairments required by 9.1 and complying with 9.3 shall be provided in the accessible sleeping room or suite....
- TotTurf® Synthetic Grass: Play Spaces
-
Alarms: ADA Standard Section 806.3.1
Where emergency warning systems are provided, alarms complying with 702 shall be provided.
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
C. Costs and Benefits
As such, the final rule does not directly impose any obligations on health care providers or medical device manufacturers....
-
H. Door Maneuvering Clearance
.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor space on the latch side for persons...
-
M301.4.1 Clearance in Base
[See subsections ...]
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...