Destination-oriented elevators shall comply with Section 11B-411 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....
Search Results "Comply With"
-
11B-411.1 General
-
11B-808.2 Turning space
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with Section 11B-304....
-
11B-1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951. Ground surfaces shall be inspected and maintained regularly and frequently to ensure continued compliance with ASTM F 1951....
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
11B-611.2 Clear Floor Space
A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance....
-
11B-235.3 Boarding piers at boat launch ramps
Where boarding piers are provided at boat launch ramps, at least 5 percent, but no fewer than one, of the boarding piers shall comply with Section 11B-1003.3.2....
-
Edge Protection: ADA Standard Section 1005.3
Where railings, guards, or handrails complying with 1005.2 are provided, edge protection complying with 1005.3.1 or 1005.3.2 shall be provided. Advisory 1005.3 Edge Protection....
-
Boarding Piers at Boat Launch Ramps: ADA Standard Section 1003.2.2
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
Counters: ADA Standard Section 227.3
Section 227.3 covers scoping requirements in the current ADA Standards for counters.
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers and sanitary napkin disposal units shall comply with Section 11B-604.7....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication features...
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-233.3.4.1 Alterations to vacated buildings
building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall comply...
-
1.1.8 City, county, or city and county amendments, additions or deletions
limit the authority of city, county, or city and county governments to establish more restrictive and reasonably necessary differences to the provisions contained in this code pursuant to complying...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers and sanitary napkin disposal units shall comply with Section 11B-604.7....
-
11B-233.3.5 Dispersion
Residential dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4 and residential dwelling units required to provide communication features...
-
11B-233.3.4.1 Alterations to vacated buildings
building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units shall comply...
-
11B-214.3 Clothes dryers
Where three or fewer clothes dryers are provided, at least one shall comply with Section 11B-611....
-
11B-224.8.2 More than 50-bed facilities
Facilities with more than 50 beds that provide common use bathing facilities, shall provide at least one roll-in shower with a seat that complies with Section 11B-608....