Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
Search Results "Pull Side"
Commonly Searched Documents
-
608.5.3 Alternate Roll-In Type Shower Compartments
-
11B-608.2.2.1 Clearance
[2010 ADAS] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-608.2.2.1 Clearance
[2010 ADA Standards] EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the...
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System Side View
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System Side View
- American Standard Madera 1.28 gpf EverClean Toilet with Exposed Manual Flush Valve System Side View
-
ELKAY Filtered EZH2O® Mechanical Surface Mount with Battery-powered visual monitor LMASMB Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Round Corners Medium Capacity Towel Dispenser & 12 Gallon Waste 234-10 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Round Corners Medium Capacity Towel Dispenser & 12 Gallon Waste 234-11 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
Do access aisle borders (in blue) have to be painted on all four sides to be considered compliant?
I would say yes as the language in the code is pretty specific using the term "perimeter". I would also say that both of the "end" lines would/could be within the required length.
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
T213.3 Armrests at Aisle Seats on Over-the-Road Buses
Where armrests are provided on the aisle side of seats on over-the-road buses, folding or removable armrests shall be provided on the aisle side of at least 50 percent of aisle seats....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
4.2.4.2 Relationship of Maneuvering Clearance to Wheelchair Spaces
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
Accessible Presentation / Speaker’s Platform - Talk Show Style
Side tables should be provided (for water, notes, or other materials) for each guest. Individuals who use wheelchairs or scooters may need a higher side table than other guests....