The California Building Code (CBC) accessibility provisions are applicable to new construction projects as well as alterations (as defined) of existing buildings and facilities....
Search Results "Multifamily Housing Project (HUD 504)"
-
1.1.3 Scope
-
609.3 Spacing
The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
4. What types of child welfare programs and activities are covered by these laws?
All activities of child welfare agencies are covered by Title II and Section 504, including removal proceedings and agencies’ programs and activities must not discriminate on the basis of...
-
Section 37.21 Applicability—General
Unlike section 504, the ADA and its implementing rules apply to entities whether or not they receive Federal financial assistance. They apply to private and public entities alike....
-
II-1.1000 General
It additionally extends the prohibition of discrimination on the basis of disability established by section 504 of the Rehabilitation Act of 1973, as amended, to all activities of State...
-
Bias Toward Wheelchair Users
The proposed guidelines, and the final Guidelines, reflect the accessibility requirements contained in the Fair Housing Act....
-
Section 2. Undisturbed site
"Undisturbed site" means the site before any construction, levelling, grading, or development associated with the current project....
-
“Disabilities” rather than the term “handicaps”
As originally noted by the House Committee on the Judiciary, “[t]he use of the term ‘disabilities' instead of the term ‘handicaps' reflects the desire of the Committee to use the most current...
-
12209(b)(2)(B)(II)
.-- The resolution referred to in clause (i) is House Resolution 15 of the One Hundred First Congress, as agreed to January 3, 1989, or any other povision that continues in effect the provisions...
-
How to Use This Pocket Guide
Elements in compliance with an earlier standard issued pursuant to the Architectural Barriers Act or Section 504 of the Rehabilitation Act of 1973, as amended shall not be required to comply...
-
Stairs
Full handrail extensions at stairs are not required where they would project hazardously into circulation paths (§505.10, Ex. 3)....
-
11B-216.8.1 Geometric symbols
Geometric symbols shall not be required at entrances to inmate toilet rooms and bathing rooms in detention and correctional facilities where only one gender is housed....
-
11B-232.5.1 Cubicles and counters
Exception: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with Section 11B-232 shall not...
-
11B-232.5.1 Cubicles and counters
Exception: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with Section 11B-232 shall not...
-
11B-216.8.1 Geometric symbols
Geometric symbols shall not be required at entrances to inmate toilet rooms and bathing rooms in detention and correctional facilities where only one gender is housed....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
11B-504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
11B-504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
11B-504.5 Nosings
Nosings that project beyond risers shall have the underside of the leading edge curved or beveled....
-
404.2.3 Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-