Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
Search Results "Curb Ramp Width"
-
1007.7.6 Stairway
-
1009.7.4 Stairways
Stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a minimum clear width of 48 inches (1220 mm) between handrails....
-
§ 38.159(c)(1) Design load
Ramps 30 inches (760 mm) or longer shall support a load of 600 pounds (2665 N), placed at the centroid of the ramp distributed over an area of 26 inches by 26 inches (660 mm by 660 mm),...
-
Portable ramp - greater than six inch step
[See subsections ...]
-
H17
H17. Is at least 9 inches of toe clearance provided under the front wall and at least one side wall of the toilet stall? [ADA Standards § 4.17.4] Yes No
-
B2
B2. Does each accessible parking space have its own, or share, an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Standards § 4.6.3] Yes No
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
A2. Access Aisle
A2. Does each accessible parking space have its own, or share an adjacent access aisle that is least 60 inches (5 feet) wide? [ADA Stds 4.6.3] Yes _____ No _____
-
8.4 Card Catalogs and Magazine Displays
Minimum clear aisle space at card catalogs and magazine displays shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1220 mm) preferred...
-
8.4 CARD CATALOGS
Minimum clear aisle space at card catalogs, magazine displays, or reference stacks shall comply with Fig. 55. Maximum reach height shall comply with 4.2, with a height of 48 in (1370...
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
Americans with Disabilities Act (ADA) Standards for Transportation Facilities
based on the Board's ADA Accessibility Guidelines (ADAAG) but include additional requirements concerning: Location of Accessible Routes (206.3) Detectable Warnings on Curb...
- citEcar Wheelchair 6PR SL Street Legal Golf Cart
- seca 664 Digital Wheelchair Scale with Wireless Transmission
-
§ 38.125(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates stowed in the passenger...
- Lift-U® LU12 Step/Platform Onboard Lift
-
§ 38.83(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
R407.6.1 Slope
R407.6.1 Slope. Landing slopes shall be 2 percent maximum in any direction.
-
1013.3 Height
On ramps, from the ramp surface at the guard. Exceptions: 1. ...
-
T202 Accessible Means of Boarding and Alighting
These vehicles must also provide access to the roadway in the event passengers must be offloaded where there is no platform or curb....
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop....
- Detecto FHD Series Stationary Wheelchair Scale
-
Requirements to Remember for ADA Compliance in Construction Projects: Transportation Facilities
Access Board’s updated ADA (and ADAAG) guidelines but includes a few additional requirements concerning: Location of Accessible Routes (206.3) Detectable Warnings on Curb...
-
9.2* POST OFFICE LOBBIES
Clear passageways in front of customer service counters shall be not less than 48 in (1220 mm) clear width to permit maneuvering of a wheelchair....