The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
Search Results "Adjustable Height Exam Table"
-
11B-1002.6.2 Transfer height
-
11B-1002.6.2 Transfer height
The height of transfer device seats shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the load and unload surface....
-
III. CONCLUSION
For the foregoing reasons, neither Section 904.4.1 nor its exception requires clear counter space at sales and service counters subject to the ADA’s requirements.
-
4.3.5 Patient Positions During Diagnostic Imaging
4.3.5 Patient Positions During Diagnostic Imaging Finally, the vast majority of diagnostic imaging exams are conducted while patients are supine, prone, or side-lying on the table....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
11B-1002.5.2 Transfer height
The height of amusement ride seats designed for transfer shall be 14 inches (356 mm) minimum and 24 inches (610 mm) maximum measured from the surface of the load and unload area....
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
Medical examination tables and chairs, on the other hand, are lowered to a low height to facilitate transfer, then are raised to a considerable height to facilitate medical examinations...
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-309.3 Height
Operable parts shall be placed within one or more of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor. Front loading machines shall have the bottom of the...
-
11B-811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
- Allegion Von Duprin 98/99 Series Von Duprin CVC Traditional Bottom Latch Adjustment