Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
Search Results "Swing Clear Hinge"
-
11B-703.4.2 Location
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
Turnstiles and Security Gates at Entrances
Turnstiles and Security Gates at Entrances Businesses with narrow revolving turnstiles located at the entrance exclude people with disabilities unless accessible gates or passages...
-
T502.3 Doorways with Level Boarding
Doorways on non-rail vehicles designed for level boarding bus systems shall comply with T502.3.
-
9.2.2(3)
(3) Doors and doorways designed to allow passage into and within all sleeping rooms, suites or other covered units shall comply with 4.13.
-
9.4 Other Sleeping Rooms and Suites
Doors and doorways designed to allow passage into and within all sleeping units or other covered units shall comply with 4.13.5.
-
§ 38.153(c)(2) Exception
(2) Exception. Where compliance with the door width requirement of paragraph (c)(1) of this section is not feasible, the minimum door width shall be 27 in (685 mm).
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2.
-
11B-809.8 Doors
The clear width of doors shall comply with Section 11B-404.2.3. Door hardware shall comply with Section 11B-404.2.7. Door surfaces shall comply with Section 11B-404.2.10....
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door....
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door....
-
§ 38.127(c)
conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48 inches, and no less than 15 inches, above the floor and shall have a clear...
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door....
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
809.2.6 Weather Alert Systems
in emergency transportable housing units, this section requires the operable parts on weather alert systems in units with mobility features to comply with the technical requirements for clear...
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- McGuire Manufacturing Co., Inc. 155CRSWC: Offset Lavatory Strainer with Chain and Rubber Stopper
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and the...
- BEA Inc. LZR-Microscan Swinging Door Sensor