- Figure 409.4.6.2 Location of Private Residence Elevator Control Panel – Drawing from the U.S. Access Board
-
4(4)
(4) Except as noted in paragraphs (5) and (6) below, thresholds at exterior doors, including sliding door tracks, are no higher than 3/4 inch....
-
11B-233.3.1.2.6.5 Additional requirements.
Interior door opening width complying with Section 11B-404.3.1. 3. Door and gate hardware complying with Section 11B-404.2.7. 4....
-
Toilet Compartment Access
If you look at 604.8.1.2 Doors, it says, "Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment...
- AD Systems’ Exam Room Doors
- 604.6 Flush Control Reach Range
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System ADA Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System Weather Resistant Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System Sectional Ramp Sill
Requires the Premium User plan or above. (Login or upgrade your account!)
-
D4
On the latch, pull side of the door, is there at least 18 inches clearance provided if the door is not automatic or power-operated?...
-
Requirement 3 -- Usable Doors
[See subsections ...]
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
T502 Doorways
[See subsections ...]
-
§ 38.93 Doorways
[56 FR 45756, Sept. 6, 1991, as amended at 76 FR 57939, Sept. 19, 2011]
-
Push Plates, Buttons, and Bars
Push-activated controls not requiring more than 5 lbf are acceptable. Buttons that are raised or flush are easier to use than those that are recessed....
- DORMA 8900 Series Door Closer
-
§ 38.113(c) Signals
If doors to the platform close automatically or from a remote location, auditory and visual warning signals shall be provided to alert passengers of closing doors...
-
Height [4.27.3]
Height [4.27.3] The operable portions of controls and operating mechanisms must be within established reach ranges for either a forward or side reach as required in 4.2.5 and 4.2.6 (see...
-
611.3 Operable Parts
Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with 309....
-
611.3 Operable Parts
Operable parts, including doors, lint screens, and detergent and bleach compartments shall comply with 309....