EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices....
Search Results "Closer Height"
-
703.4.2 Location
-
Location [4.6.2] and Dispersion
For example, spaces for an out-lying lot can be placed in a lot closer to the building served since accessible spaces must be located on the shortest accessible route to an accessible facility...
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic and power-assisted doors are often used by designers to provide accessibility when door closer pressure would exceed the allowable opening force for interior or exterior doors....
-
703.4.2 Location
EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices....
-
5.8.3 Breast Platform Recommendations
Platform Recommendations Description: In addition to providing knee and toe clearance at the breast platform (see 5.8.2 Knee and Toe Clearance Recommendations under Breast Platforms), the height...
-
Operable Parts of Windows
The referenced technical criteria address the operable parts of windows, including that such parts be within accessible reach ranges, but they do not address the height of glazed openings...
-
Executive summary
Results showed that height differentials above and below WMD seat height, gaps and obstacles pose serious transfer-related accessibility problems for WMD users therefore suggesting the need...
-
Single Occupant Structures (§203.6)
Single Occupant Structures (§203.6) Single occupant structures accessed only by below-grade passageways or elevated above standard curb height Examples: toll booths that are accessed...
-
§ 38.73(d)(3) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
§ 38.53(d)(3) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
407.12.2.1 Unobstructed Side Reach (Section-by-Section Analysis)
Although existing 508 Standards § 1194.25 (j)(2) permits a maximum reach height of 54 inches, it contains the same minimum height (15 inches) and 10-inch reach depth....
-
§ 38.23(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. ...
-
2.7 Tread Obstacles
Where tread obstacles exist on the surface of an ORAR, they shall not exceed 1 inch (25 mm) in height....
-
§ 38.29(f)
(f) For vehicles in excess of 22 feet in length, the minimum interior height along the path from the lift to the securement location shall be 68 inches....
-
4.3.1 Reference WhMD Users
At minimum, the Reference WhMD Users should have data on unoccupied and occupied length and width, total occupied height, eye height and armrest height....
-
Identification: ADA Standard Section 809.5.5.2
Such peepholes can be placed at a standard height and permit a view from several feet from the door....
-
BENEFITS AND COSTS: SUMMARY
BENEFITS AND COSTS: SUMMARY Therefore, while establishing these requirements will result in significant costs to health care providers, establishing a lower adjustable height requirement...
-
7.4.6 Tread Obstacles
Tread obstacles on trails shall not exceed 2 inches (50 mm) in height measured vertically to the highest point. ...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
1010.1.7 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished floor...
-
§ 38.53(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
§ 38.73(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....