Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
Search Results "Lavatory Height"
Commonly Searched Documents
-
11B-226.3 Dining surfaces exceeding 34 inches in height
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be permitted to extend beyond...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2. EXCEPTION: Where fixed overhead patient...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M301.4.1 or M301.4.2.
-
M301.2.3 Transfer Sides
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface. Each transfer side...
-
Protocol B Heights Obtained
Again for the minimum height protocol HERL participants transferred lower on average than the NDVWSC participants....
-
11B-611.4 Height
11B-611.4 Height. Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
- Access Board: Signs
-
11B-611.4 Height
FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING...
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
How Can You Overcome These Barriers to Work with Your Providers?
There are many things that a person with a disability can do to improve his or her quality of health care and break down the barriers that compromise care. The following suggestions...
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position
[See subsections ...]
-
Appendix 3 - Comparison of US Standards to IDEA Center Research
(HH) 915 80 895 754 1024 Armrest Height (AH) 760...
- Boost Your Business - Chapter 11 - Stairs
-
3.3.7 Toe Clearance Height, minimum
3.3.7 Toe Clearance Height, minimum There is relatively large disparity between the standards for toe clearance height, with the U.S. having the lowest (230 mm or 9 in.), followed by...
-
COSTS TO LOWER MINIMUM TABLE HEIGHT
COSTS TO LOWER MINIMUM TABLE HEIGHT To be useful for its intended purpose, examination tables and chairs must maintain a high height of at least 32 inches, so that the health care provider...