Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
Search Results "Hoistway Clearance"
-
604.3.1 Size
-
References:
“Clearance Space Envelopes of Wheeled Mobility Device Users for Computer Workstations”. Proceedings of the Human Factors and Ergonomics Society Annual Meeting 2012....
-
Conclusions
Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
Recessed Lavatories
In-swinging doors must clear fixture clearances and door clearances must clear the water closet fixture (verify toilet length)....
-
Water Closet Clear Floor Space in Toilet Compartments
Water closets not in compartments require clearance that is at least 60 inches wide and 56 inches deep....
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
§ 38.25(c) Door height
For vehicles in excess of 22 feet in length, the overhead clearance between the top of the door opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68...
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
Water Closet Clear Floor Space
Clearance requirements for water closets are covered in section 604.3....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
-
Limited-Use/ Limited-Application Elevators [§408]
Besides car size, provisions for LULAs differ from those of §407 in that: Hoistway doors can be swinging type (they must open and close automatically, be power-operated, meet requirements...
-
Recessed Objects
Elements, such as wheelchair accessible drinking fountains, must provide a knee clearance of at least 27”....
-
Floor and Ground Surfaces
apply to: interior and exterior accessible routes, including walking surfaces, ramps, elevators, and lifts stairways that are part of a means of egress required clearances...
-
R210.3 Shared Use Paths
The AASHTO Guide recommends 10 feet vertical clearance along shared use paths, and 8 feet minimum vertical clearance in constrained areas....
- Pilot Rock WPTS Square Frame Table Using Recycled Plastic
- Pilot Rock WPTS Square Frame Table Using Lumber
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
306.1 General
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support for an element....
-
11B-603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
603.2.2 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....