Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
Search Results "Clear Space"
Commonly Searched Documents
-
1134A.4 Sufficient maneuvering space
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
§ 38.93(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...
-
1134A.4 Sufficient maneuvering space
Where the door swings into the bathroom or powder room, there shall be a clear maneuvering space outside the swing of the door of at least 30 inches by 48 inches (762 mm by 1219 mm) within...
-
304 Turning Space
304 Turning Space Section 4.2.3 of the 1991 Standards and Section 304.3 of the 2010 Standards allow turning space to be either a circular space or a T-shaped space....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
Check-Out Aisles: ADA Standard Section 227.2
Section 227.2 covers scoping requirements in the current ADA Standards for check-out aisles.
-
R302.3.1 Medians and Pedestrian Refuge Islands
The clear width of pedestrian access routes within medians and pedestrian refuge islands shall be 1.5 m (5.0 ft) minimum....
-
R302.3.1 Medians and Pedestrian Refuge Islands
The clear width of pedestrian access routes within medians and pedestrian refuge islands shall be 1.5 m (5.0 ft) minimum....
- Figure 502.3 Parking Space Access Aisle – Drawing from the U.S. Access Board
-
Overlapping Wheelchair Turning Space
A provision in section 807.2.1 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as discussed...
-
Overlapping Wheelchair Turning Space
A provision in section 806.2.6 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as discussed...
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
11B-1008.4.1 Turning space
At least one turning space complying with Section 11B-304 shall be provided on the same level as play components....
-
Appendix 3 - Comparison of US Standards to IDEA Center Research
607 Eye height (EH) 1090-1295 75 1174 1047 1288 Clear...
-
1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
11B-1009.3.3 Handrails
The clear width between required handrails shall be 33 inches (838 mm) minimum and 38 inches (965 mm) maximum....
-
Attachment H
Provide a paper towel dispenser with the controls a maximum height above the finished floor of 48 inches for a forward approach or 54 inches for a side approach and that is accompanied by clear...