Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of Sections 11B-603 through 11B-610....
Search Results "Bathtub Clearance"
Commonly Searched Documents
-
11B-805.2.4 Toilet and bathing rooms
-
FIGURE INDEX
in an Alcove, Forward Approach Figure 305.7.2 Maneuvering Clearance in an Alcove, Parallel Approach Figure 306.2 Toe Clearance Figure 306.3 Knee Clearance Figure...
-
Priority 3: Toilet Rooms
Word Fillable Form (2.4MB) Word Non-Fillable Form (2.2MB) PDF Non-Fillable Form (0.7MB)
- The Corada Shop
-
Grab bar clearance
Have local authorities accepted one-piece dispensers in toilet compartments that are recessed behind the horizontal grab bars? These units stick out ¼" or so. ANSI 117.1 allows it...
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
17. Maneuvering Clearances and Hardware
[See subsections ...]
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—in-swinging doors (Req. # 32)
For the water closet clearance in single-user toilet rooms with the in-swinging door requirement (Req. #32), the expert panel determined that the primary beneficiaries would be persons who...
-
Toilet and Bathing Rooms: ADA Standard Section 805.4
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
Priority 2: Access to Goods & Services
Word Fillable Form (2.5MB) Word Non-Fillable Form (2.4MB) PDF Non-Fillable Form (1.4MB)
-
H29
For information on the requirements for accessible showers or bathtubs see the ADA Standards for Accessible Design which is available online at www.ada.gov....
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Requirement: 4.21.2 Size and Clearances. Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b)....
- Boost Your Business - Chapter 3 - Path of Travel
- Access Board: Sales and Service Counters
-
Polling places that cannot be remediated with temporary measures:
Building Entrance & Voting Area: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds...
-
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
Attachment J: Access to Humboldt County Programs Housed in Others’ Facilities
-
Toilet and Bathing Facilities: ADA Standard Section 807.2.4
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
-
805 Medical Care and Long-Term Care Facilities
Commenters opposed this requirement, noting that it is inconsistent with specifications for wheelchair turning space in section 304 which recognize knee and toe clearances for specified...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made concerning...