SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
-
Conclusions
No studies or measurement of transfers were recorded nor did we collect information on the space needs of other tasks on exam tables like repositioning the body for exams....
-
Head and Back Support (M301.3.3 and M302.3.3)
This is consistent with ANSI/AAMI HE75 which recommends that the “support surface needs to be adjustable or have adjustable support features (e.g., for the head, neck, back, lumbar region...
- 2101KL HR Digital Platform Scale with Mechanical Height Rod
-
1. Getting Started
It also means getting to and into the office, getting on the exam table and the equipment and getting equal care as that provided to others. ...
-
Appendix B to Part 382—Cross-Reference Table
The Department is providing the following table to assist users familiar with the current Part 382 in finding material in the new, renumbered Part 382....
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less in height...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
M301.2.2 Transfer Surface Size
All X-Ray tables meet the 28 inch table width for item “B”....
-
M301.2.2, M302.2.2 Transfer Size
This transfer surface is located on the longitudinal (long) side of the stretcher—either right or left side Rationale: Based upon full committee discussion and harmonization with Exam...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface....
-
M301.3.3 Head and Back Support
This is consistent with ANSI/AAMI HE 75 which recommends that the “support surface needs to be adjustable or have adjustable features (e.g., for the head, neck, back, lumbar region, leg,...
-
B. Legal foundation for equipment and furniture coverage
For example, the provision of a height adjustable examination table in a doctor's office may meet the requirement for program accessibility....
-
ETA Summary of ADAAG/CBC Signage Requirements
ADAAG/CBC Signage Requirements Click here to view/download the pdf version (1.22 MB)
-
ETA Summary of ADA Signage Requirements
Summary of ADA Signage Requirements Click here to view/download the pdf version (162 KB).
-
6.1 Deliberative Process
At its first meeting, the Advisory Committee considered this NPRM recommendation of 17” to 19”, which applied to either fixed or adjustable height transfer surfaces....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
811.3 Height
Storage elements shall comply with at least one of the reach ranges specified in 308. [ECTCR UFAS 4.34.6.10(2)]
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.