Within thirty (30) days of the entry of this Consent Decree, the County will adopt and follow the attached Notice under the Americans with Disabilities Act, Attachment A (“Notice”)...
Search Results "Side Entry"
-
B. NOTIFICATION
-
Employee Work Areas [§206.2.8]
However, these types of employee work areas still must be accessible for “approach, entry, and exit” (§203.9)....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
11B-406.5.3 Landings
The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing....
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
1023.9 Stairway identification signs
braille floor identification signs that comply with Chapter 11A, Section 1143A or Chapter 11B shall be located at the landing of each floor level, placed adjacent to the door on the latch side...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
1132A.4, Item 1
., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm) of change in height between floor surfaces....
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
Is front-in only or angled parking prohibited for accessible parking spaces?
However, where van spaces are angled, the Standards require the access aisle to be located on the passenger side which is the side where vehicle ramps and lifts are typically deployed....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
11B-604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
A4.15.2 Spout Height
Two drinking fountains, mounted side by side or on a single post, are usable by people with disabilities and people who find it difficult to bend over....