Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
Search Results "Raised Judging Area"
-
M303.3.3 Ramped
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the...
-
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides
5.8.1.2.3 Double Ramped Entry – Edge Protection on the Platform Sides. A minimum 2 inch high edge protection must be provided on both sides of the platform for double ramped entry...
-
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides
5.8.1.2.2 Single Ramped Entry – Edge Protection on the Platform and Platform Sides. A 2 inch high edge protection must be provided on the back of the platform, opposite the entry...
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height Recommendations The Committee recommends that no edge protection be required on platforms of 1½ inches or less...
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations The Committee recommends a minimum two-inch high edge protection on both sides of the...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side.
-
11B-703.4 Installation height and location
11B-703.4 Installation height and location. Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
703.4 Installation Height and Location
703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4.
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.
-
Temporary Suspension
Temporary Suspension In response to business and user concerns about the need for the detectable warnings specified in 4.29 at curb ramps and hazardous vehicular areas, the Access Board...
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
Viewing areas often provide more than one distinct viewing location....
-
203 General Exceptions
Used Only by Employees as Work Areas: Areas Used Only by Employees as Work Areas....
-
F219.2 Required Systems
In each assembly area where audible communication is integral to the use of the space, an assistive listening system shall be provided....
-
F203.8 Detention and Correctional Facilities
In detention and correctional facilities, common use areas that are used only by inmates or detainees and security personnel and that do not serve holding cells or housing cells required...
-
219.2 Required Systems
In each assembly area where audible communication is integral to the use of the space, an assistive listening system shall be provided....
-
203.7 Detention and Correctional Facilities
In detention and correctional facilities, common use areas that are used only by inmates or detainees and security personnel and that do not serve holding cells or housing cells required...
-
1009.4 Elevators
The elevator shall be accessed from an area of refuge complying with Section 1009.6....