The standards specify a maximum height (27”) for the leading edge of barriers so they are within cane sweep, but a minimum height is not specified. Curbs may be mistaken for a step...
Search Results "On-Call Room"
Commonly Searched Documents
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
-
§ 38.107(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an...
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a 36 inch (914 mm) by 48 inch (1219 mm) minimum clear space on both sides of a bed. The clear space shall be positioned for parallel approach...
-
703 Signs
specifications for the height of visual characters (703.5.6) revising the location of text descriptors of pictograms (703.6.3) Scoping requirements for signs in section 216 cover room...
- Paratransit Emergency Preparedness and Operations Handbook
-
Common Problems with Signs
Common Problems with Signs Ø Some signs – such as permanent room signs – are required to have Braille, high contrast, and raised lettering and must be located on the wall to the...
-
224.1 General
Transient lodging facilities shall provide guest rooms in accordance with 224. Notwithstanding the requirements of this section, section 201.1.1 shall apply....
- The Mayer-Rothschild Foundation
-
Character Height: ADA Standard Section 703.5.5
Minimum character height shall comply with Table 703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing further...
-
11B-703.5.5 Character height
Minimum character height shall comply with Table 11B-703.5.5. Viewing distance shall be measured as the horizontal distance between the character and an obstruction preventing...
-
Operating Hardware
Result: Persons who have the use of only one hand or who have limited use of hands, wrists, or arms are unable to open doors to get into rooms, lock doors for security, use sinks or showers...
-
9.2.2(7) Kitchens, Kitchenettes, or Wet Bars
When provided as accessory to a sleeping room or suite, kitchens, kitchenettes, wet bars, or similar amenities shall be accessible....
-
Access To Medical Care For Individuals With Mobility Disabilities
Additional copies may be obtained by calling the ADA Information Line at 800‒514‒0301 (voice), 800‒514‒0383 (TTY). July 2010...
-
Rooms and Spaces: ADA Standard Section 206.5.2
Section 206.5.2 covers scoping requirements in the most current ADA Standards for accessible routes to rooms and spaces.
-
7. Training Call Takers to Respond Effectively to TTY Calls
PSAPs should train their call takers to effectively recognize and process TTY calls. Providing appropriate equipment is only as effective as your staff training....
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
-
(3) Usable bathrooms
The final Guidelines for usable bathrooms also provide that the usable bathroom specifications (either set of specifications) are applicable to powder rooms (i.e., a room with only a toilet...
-
§ 35.151(f) Housing at a place of education.
subject to this section shall comply with the provisions of the 2010 Standards applicable to transient lodging, including, but not limited to, the requirements for transient lodging guest rooms...
-
Problem One (Protruding Objects)
Problem One: Objects, such as branches and ceiling-mounted televisions, over a route are lower than 80 inches above the ground or floor. Solution: Prune the branches or remove the...