Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
Search Results "Flared Side"
-
610.3 Shower Compartment Seats
-
Forward Approach
Forward Approach Drinking fountains are easier to use from a forward approach than from a side approach. Clearances for a forward approach are required at cantilevered units....
-
FAQ: How do I enter ADA references in my Voices post?
Begin to type a section number relevant to your post, for example "308.3" or the section name, for example "side reach."...
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
Ramps with drop offs ½ inch or greater would be required to provide edge protection 2 inches high minimum on each side to prevent users from inadvertently travelling off the sides of the...
-
Signage
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
1115B.4.1, Item 1
Therefore, existing water closets permitted and/or installed when those regulations were applicable with their centerlines located nominally more than 18 inches from the side wall should...
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Camp Shelter
Camp Shelter—A small structure typically enclosed on three sides with a roof or overhang to provide campers and hikers cover from weather....
-
Camp Shelter
A small structure typically enclosed on three or all four sides, with a roof or overhang. Camp shelters are often located on trails. ...
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
1132A.2 Interior doors and secondary exterior doors
The provisions of this section shall apply to the dwelling unit side of doors leading from the interior of the dwelling unit to an unfinished basement or an attached garage....
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
- Magnuson Group VOICI Magazine Racks
-
802.1.3 Depth
Where a wheelchair space can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
7. Grab Bars
Are there two horizontal grab bars (one high/one low) along the side of the tub that are at least 24" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat -...
-
e-vi
Are signs mounted on both sides of the elevator hoist way door opening (for each elevator and at each floor) that designate the floor with 2-inch minimum-height raised letters and Braille...
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
M303.2.3 Depth
Where wheelchair spaces can be entered only from the side, the wheelchair space shall be 60 inches (1525 mm) deep minimum....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
M303.2.6 Edge Protection
provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the platform shall be provided on each side...
-
Aisle Stairs and Ramps in Assembly Areas
Section 4.8.5 of the 1991 Standards exempts aisle ramps that are part of an accessible route from providing handrails on the side adjacent to seating....