Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
Search Results "Elevated Play Component"
-
11B-411.2.1.5.1 Size
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-409.4.7.1 Type
A telephone and emergency signal device shall be provided in the car.
-
11B-407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses.
-
11B-411.2.1.5.2 Color
Characters and symbols on buttons, where provided, shall be white on a black background.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum.
-
11B-409.4.3 Platform to hoistway clearance
The clearance between the car platform and the edge of any landing sill shall be 1½ inch (38 mm) maximum.
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309.
-
11B-409.4.7.2 Operable parts
The telephone and emergency signaling device shall comply with Sections 11B-309.3 and 11B-309.4.
-
11B-409.4.7.4 Cord
The telephone cord shall be 29 inches (737 mm) long minimum.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-411.2.1.5.1 Size
Buttons shall have square shoulders, be 3/4 inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
Machinery Spaces: ADA Standard Section 203.5
Section 203.5 covers scoping requirements of general exceptions for machinery spaces in the most current ADA Standards.
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
11B-203.5 Machinery spaces
Machinery spaces include, but are not limited to, elevator pits or elevator penthouses; mechanical, electrical or communications equipment rooms; piping or equipment catwalks; water or sewage...
-
1008.2.6 Ground Surfaces
The type of surface material selected and play area use levels will determine the frequency of inspection and maintenance activities....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
409.4.2 Floor Surfaces
Floor surfaces in elevator cars shall comply with 302 and 303....
-
1008.2.6 Ground Surfaces
The type of surface material selected and play area use levels will determine the frequency of inspection and maintenance activities....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
In non-elevator buildings, a minimum of 10 percent but not less than one of the ground floor multi-story residential dwelling units shall be calculated using the total number of multi-story...