The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
Search Results "ETA: Evan Terry Associates"
-
Lavatory & Accessory Layouts
-
California Water Closet Accessories
Design guidance for locating water closet accessories in single user toilet rooms and best practice placement of the lavatory in new construction giving the owner more options to...
-
Re: How to Use the Pressure Gauge Tool
WARNING - We have stopped carrying the HMC International spring-type door pressure gauges shown in the video because the last two large shipments we received were all exactly one...
- Trail Construction and Maintenance Notebook - 2007 Edition
-
§1607.5 General standards for validity studies.
standardized tests and other selection procedures, such as those described in the Standards for Educational and Psychological Tests prepared by a joint committee of the American Psychological Association...
-
Implementation Approach and Schedule
The second phase would require all pages associated with obtaining core air travel services and information related to these core services, either to be directly conformant on the carrier's...
- Texas Society of Architects
-
11B-213.3.1 Toilet compartments
ETA Editor's Note The 2013 CBC scoping for toilet compartments was originally the same as 2010 ADAS. ...
-
11B-608.6 Shower spray unit and water
ETA Editor's Note The 2010 ADAS Exception at 608.6 allows the installation of fixed shower heads at accessible showers in fewer locations than 2013 CBC. ...
-
11B-805.7 Built-in cabinets and work surfaces
ETA Editor's Note The Office of Statewide Health Planning and Development (OSHPD), which has jurisdiction over hospitals and long-term care facilities in California, has issued Code Application...
-
11B-216.2 Designations
ETA Editor's Note The Exception at 11B-216.2 does not mention that Braille is also not required at exterior signs that are not located at the door to the space that they serve, but this...
-
206.2.1 Site Arrival Points
ETA Editor’s Note: Requirements for curb ramps, sidewalks and other elements in the public right of way may be covered by other Federal, State or local standards and regulations....
-
1013.3 Height
ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted. ...
-
2.3.2. Device Acquisition
Figure 2-3 : Calculation Diagram for Captioning and Audio Description Device Acquisition ETA Editor's Note As of 11/21/16 (this document's publication date), Figure 2-3 is not shown...
-
2.2. Total Costs
Figure 2-1 : Overview of Methodology for Calculating Total Costs ETA Editor's Note As of 11/21/16 (this document's publication date), Figure 2-1 is not shown. 8 Office...
-
1015.3 Height
ETA Editor's Note Sections from California Building Code Chapter 10 that are not adopted by the Division of the State Architect - Access Compliance (DSA-AC) have been omitted....
-
11B-216.2 Designations
ETA Editor's Note The Exception at 11B-216.2 does not mention that Braille is also not required at exterior signs that are not located at the door to the space that they serve, but this...
-
11B-608.6 Shower spray unit and water
ETA Editor's Note The 2010 ADAS Exception at 608.6 does not require the consideration of excessive vandalism or the installation of two shower heads where fixed ones are provided....
-
SHOPPING CENTER (OR SHOPPING MALL)
. ◼ ETA Editor's Note CBC defines a single, stand alone retail store as a shopping center and, therefore, requires storage mezzanines to be served by an accessible route....
-
11B-224.8.2 More than 50-bed facilities
ETA Editor's Note The following Access Board Note was taken from ADA Title II §35.151(e) New Construction and Alterations; Social Service Center Establishments, and ADA Title III §36.406...
-
11B-205.1 General
ETA Editor's Note The ADA requirement included at Section 11B-205.1 Exception 3 is provided for information only. The CBC scoping requirement is more inclusive. 4....
-
11B-608.6 Shower spray unit and water
. ◼ ETA Editor's Note The 2010 ADA Standards Exception at 608.6 does not require the consideration of excessive vandalism or the installation of two shower heads where fixed ones are...