The cam action design is ideal as it provides greater efficiency than a rack and pinion door closer for slide track applications. ...
Search Results "Door Timing"
Commonly Searched Documents
- Norton Surface Mounted 2800ST Cam Action Closer
- Rockwood Manufacturing Company 11047 Series 47 Straight Single Bar Set 8" Pull CTC
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Features include a standard bathtub with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room....
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Features include a standard bathtub with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room....
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
- Horton Automatics EasyAccess® Series 7100 for ADA Low Energy Applications
- NYC Board of Elections: Video 3 - Accessibility Clerk Responsibilities
- Cavity Sliders USA Inc. Pocket Insert Track
- SDC EMLock® Magnetic Lock
- Access Board: Maneuvering Clearances at Doors
- Cal-Royal CR6000 Series Digital Touch Screen Door Lock
-
Amenities
Doors shall not swing into the clear floor space required by 903.2. 404 Doors, Doorways, and Gates. 404.2.3 Clear Width. Door openings shall provide a clear width of 32 inches minimum....
- HEWI System 111 Door Hardware
- HEWI Range 250 Door Hardware
- HEWI Range 180 Door Hardware
- HEWI Range 260 Door Hardware
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls
- Activar Hiawatha HG111 & HG112 Straight Tubular Pulls and HG113 & HG114 Push Bars
- Norton 6000 Series Low Energy Operator
-
404.2.4.4 Floor or Ground Surface
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. Slopes not steeper...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be...
-
Wheelchair Accessible Gates
Web sites with designs that allow wheelchair access while restricting access by ATVs and motorcycles are listed near the end of this tech tip. The best Web site was that of Scottish...