compliance Approved in California by OSHPD for hospital use Vinyl and non-PVC profiles are GREENGUARD certified Minimize seams with standard 12' handrail lengths Continuous...
Search Results "Continuous Width"
- Inpro Corporation IPC® 800 Handrail
- Weizel Security 826-S74 SR™ Partition Door
-
907.5.2.3 Visible alarms
A visible alarm notification appliance installed in a nurses' control station or other continuously attended staff location in a Group I-2 care suite shall be an acceptable alternative to...
-
907.5.2.3 Visible alarms
A visible alarm notification appliance installed in a nurses’ control station or other continuously attended staff location in a Group I-2 care suite shall be an acceptable alternative...
-
607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width. FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM...
-
R304.5.5 Clear Space
Beyond the bottom grade break, a clear space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided within the width of the pedestrian street crossing and wholly outside the...
-
2. b. i. Clear door openings
Clear door openings: Door openings should provide a clear width of 32 inches (815 mm) minimum....
-
§ 37.131(a)(1)(i)
(i) The entity shall provide complementary paratransit service to origins and destinations within corridors with a width of three-fourths of a mile on each side of each fixed route....
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
11B-250.1 General
Beyond the crossing where continuation of the circulation path within a parking facility leads immediately to and does not continue beyond only parking spaces complying with Section 11B-...
-
11B-250.1 General
Beyond the crossing where continuation of the circulation path within a parking facility leads immediately to and does not continue beyond only parking spaces complying with Section 11B-...
-
11B-1003.3.2 Boarding pier clearances
Every 10 feet (3048 mm) maximum of linear pier edge shall contain at least one continuous clear opening 60 inches (1524 mm) wide minimum....
-
12113(d)(2) Applications
the list developed by the Secretaryof Health and Human Services under paragraph (1), and which cannot be eliminated by reasonable accommodation, a covered entity may refuse to assign or continue...
-
1008.2.6 Ground Surfaces
Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
382.141 What training are carriers required to provide for their personnel?
This section continues, for the most part, the requirements of the existing rule. There are a few differences, in view of the rule’s application to foreign carriers....
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
1008.2.6 Ground Surfaces
Ground surfaces must be inspected and maintained regularly to ensure continued compliance with the ASTM F 1951 standard....
-
12113(e)(2) Applications
the list developed by the Secretary of Health and Human Services under paragraph (1), and which cannot be eliminated by reasonable accommodation, a covered entity may refuse to assign or continue...
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...