The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the platform during its operation....
Search Results "Assurances from Contractors"
Commonly Searched Documents
-
§ 38.23(b)(5) Platform barriers
-
§ 38.159(b)(5) Platform barriers
The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the platform during its operation....
-
§ 38.95(b)(5) Platform barriers
The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the lift during its operation....
-
3.7 Louisville Tinseltown 19, 4400 Towne Center Drive, Louisville, Kentucky
- In Auditorium 10, the four (4) wheelchair spaces shall be relocated one row farther back in the auditorium from their current location....
-
Chapter 3: Building Blocks
Substantive revisions made in the final rule include: lowering the maximum height for side reaches from 54 to 48 inches (308.3.1) providing a limited exception from this...
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
1133B.2.5.1
If the door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches...
-
Backrests
Backrests: The backrest design for platform 1, the first surface that participants transferred to from their WMD as seen in Table 2, was based on bench seat back supports in section 903.5...
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
Publicizing the ADA: Advocacy and the Government Response
During this year, representatives from the disability community began to form an ADA coalition to promote passage of the ADA....
-
4.20.2 Floor Space
Therefore, residential tubs that are only accessed from one open side, were typically designed with one end against a wall and 3 open sides from which assistance could be provided....
-
Section 36.208(a) (Section-By-Section Analysis and Response to Comments)
Section 36.208(a) implements section 302(b)(3) of the Act by providing that this part does not require a public accommodation to permit an individual to participate in or benefit from the...
-
II-3.11000 Retaliation or coercion
Individuals who exercise their rights under the ADA, or assist others in exercising their rights, are protected from retaliation....
-
1009.1 Accessible means of egress required
Where more than one means of egress are required by Section 1006.2 or 1006.3 from any accessible space, each accessible portion of the space shall be served by accessible means of egress...
-
11B-705.2 Detectable directional texture
texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm), with bars raised 0.2 inch (5.1 mm) from...
- Why Corada?
-
607.4.2.1 Back Wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
607.4.1.1 Back Wall
Each grab bar shall be installed 15 inches (380 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall. [ECTCR UFAS 4.34.5.4(3), Fig. 48(b)]...
-
Subpart B -- General Requirements (Preamble, Section-by-Section Analysis)
Subpart B -- General Requirements Subpart B includes general prohibitions restricting a public accommodation from discriminating against people with disabilities by denying them the opportunity...
-
Common Problems with Entrances and Doors
Ø Round doorknob hardware prevents someone who cannot grasp or turn a doorknob from entering....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
11B-607.4.2.1 Back wall
Each grab bar shall be 24 inches (610 mm) long minimum and shall be installed 24 inches (610 mm) maximum from the head end wall and 12 inches (305 mm) maximum from the control end wall....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...