806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
Search Results "Patient Change Area"
-
806.2.3 Sleeping Areas
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
5.9.1 Standing Supports In Reference To Mammography Equipment
5.9.1 Standing Supports In Reference To Mammography Equipment. The requirement for standing supports should be removed for mammography equipment. To be useful, positioning supports...
-
M302.2 Transfer Surface
M302.2 Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one...
-
E. Beds in nursing homes and other care facilities
E. Beds in nursing homes and other care facilities Nursing homes, assisted living facilities, and other care facilities may have beds that are too high or too low, which can be a...
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital. Recommendation: Compliance with 4.13.6 is recommended...
-
Bedside Clearances
Bedside Clearances Clearance at least 36 inches wide is required on each side of beds. Where more than one bed is provided, this space can overlap. Privacy curtains or screens...
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
11B-805.2.1 Hand washing fixtures
Hand washing fixtures shall comply with Section 11B-606.
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
§ 36.308 Seating in assembly areas
§ 36.308 Seating in assembly areas....
- National Floor Safety Institute (NFSI)
-
Alterations / Additions
Alterations / Additions The minimum number of accessible patient rooms required is based on the total number of bedrooms that are altered or added, including where a unit or department...
-
1009.2 Continuity and components
Areas of refuge complying with Section 1009.6. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
1009.2 Continuity and components
Areas of refuge complying with Section 1009.6. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge....
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
-
M305.3.3 Fittings (Section-by-Section Analysis)
The Access Board made no changes to this provision....
-
11B-204.1 General
Exceptions: Within areas of sport activity, protruding objects on circulation paths shall not be required to comply with Section 11B-307....
-
11B-204.1 General
Exceptions: Within areas of sport activity, protruding objects on circulation paths shall not be required to comply with Section 11B-307....
-
810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402....
-
810.2.3 Connection
Bus stop boarding and alighting areas shall be connected to streets, sidewalks, or pedestrian paths by an accessible route complying with 402....
-
Amusement Rides: ADA Standard Section 216.12
Section 216.12 covers scoping requirements in the current ADA Standards for signs at amusement rides.
-
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position
Transfer Surface Size – M301.2.2 Supine, Prone, or Side-Lying Position The issues were discussed and decided in the full committee meeting as follows: depth of 17 inches minimum...
-
Can People with Limited Mobility Use the Usable Circulation Path by Themselves?
A person using a wheelchair is able to travel unassisted through that portion of the usable circulation path necessary to reach an area of refuge....