The ADA requires the Access Board to ‘‘issue minimum guidelines that shall supplement the existing Minimum Guidelines and Requirements for Accessible Design for purposes of subchapters II...
Search Results "Existing ICT"
-
The Roles of the Access Board and the Department of Justice
-
11B-233.3.1.2.6.3 Test number two, site analysis test
The analysis of the existing slope (before grading) shall be done on a topographic survey with 2 foot (610 mm) contour intervals with slope determination made between each successive interval...
-
810.9 Escalators
EXCEPTION: Existing escalators in key stations shall not be required to comply with 810.9....
-
11B-407.3.3 Reopening device
Exception: Existing elevators with manually operated doors shall not be required to comply with Section 11B-407.3.3....
-
810.9 Escalators
EXCEPTION: Existing escalators in key stations shall not be required to comply with 810.9....
-
§ 36.304(d)(3)(ii)
(ii) Where an existing swimming pool has at least 300 linear feet of swimming pool wall, it shall comply with the applicable requirements for swimming pools, except that it shall be required...
-
C201.2 Readily Achievable
conformance to one or more requirements in Chapter 4 (Hardware) or Chapter 5 (Software) would not be readily achievable, it shall ensure that the equipment or software is compatible with existing...
-
12148(a)(2) Exception
(2) Exception Paragraph (1) shall not require a public entity to make structural changes to existing facilities in order to make such facilities accessible to individuals who use wheelchairs...
-
REMOVAL OF BARRIERS
A public accommodation shall remove architectural barriers in existing facilities, including communication barriers that are structural in nature, where such removal is readily achievable...
-
11B-201.1 Scope
All areas of newly designed and newly constructed buildings and facilities and altered portions of existing buildings and facilities shall comply with these requirements."1 1 "These...
-
§ 37.77(e)
ETA Editor's Note Currently, §37.71(b)-(g) referenced above, do not exist according to ecfr.gov....
-
§ 38.53(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
§ 38.73(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-407.3.3 Reopening device
Exception: Existing elevators with manually operated doors shall not be required to comply with Section 11B-407.3.3....
-
11B-407.3.3 Reopening device
Exception: Existing elevators with manually operated doors shall not be required to comply with Section 11B-407.3.3....
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-705.1.2.2.2.2 Two entrance/exit points
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-809.8 Doors
Additional amendments reflect the relocation of existing exceptions in Section 11B-809.8 to Section 11B-809.8.3.1."...
-
Is DSA aware of existing precedents (potentially from past experience with non-EV accessible parking) to address the factors that would be considered to determine whether compliance with EV accessibility rules would be technically infeasible?
RESPONSE: A request for technical infeasibility is made to and determined by the local jurisdiction. A request for technical infeasibility is site-specific; therefore, there are no...
-
On existing locations when we add an EV station as van accessible how do we address taking two spaces from the facility (losing a space) and then not having the mandatory spaces remaining for the facility?
RESPONSE: All work is required to comply with the applicable codes, standards and ordinances. Parking ordinances are typically adopted within each city and county in California....
-
§1607.12 Retesting of applicants.
Where examinations are administered periodically with public notice, such reasonable opportunity exists, unless persons who have previously been tested are precluded from retesting....