Search Results "Building Permit"
-
104.1.1 Construction and Manufacturing Tolerances
-
104.1.1 Construction and Manufacturing Tolerances
bars must be installed between 33 inches and 36 inches above the floor, the range provides an adequate tolerance and therefore no tolerance outside of the range at either end point is permitted...
-
Calculation of Percentages: ADA Standard Section 104.2
Section 104.2 of the ADA Standards covers the most current information on the calculation of percentages in the ADA Standards.
-
Approach: ADA Standard Section 802.1.4
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
11B-411.1.2 Car designations
Exception: Elevator systems with more than 26 elevators shall be permitted to use alpha-numeric designations such as “A1”....
-
11B-213.1 General
Where toilet facilities and bathing facilities are provided in facilities permitted by Section 11B-206.2.3 Exception 1 not to connect stories by an accessible route, toilet facilities and...
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
11B-104.2 Calculation of percentages
Where the determination of the required size or dimension of an element or facility involves ratios or percentages, rounding down for values less than one half shall be permitted....
-
11B-213.1 General
Where toilet facilities and bathing facilities are provided in facilities permitted by Section 11B-206.2.3 Exception 1 not to connect stories by an accessible route, toilet facilities and...
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
11B-411.1.2 Car designations
Exception: Elevator systems with more than 26 elevators shall be permitted to use alpha-numeric designations such as “A1”....
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units constructed...
-
Sec. 469.003(d)
(d) If any portion of a building described by Subsection (a)(1) is occupied solely for residential use and the remaining occupied portion of the building is occupied for nonresidential use...
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-411.1.1 Floor designations
installed or existing elevators are altered into a destination-oriented elevator system, levels within stories, such as mezzanines located above or below the main entry level shall be permitted...
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
11B-1009.2.7 Operation
The lift shall be stable and not permit unintended movement when a person is getting into or out of the seat. [2010 ADA Standards] 1009.2.7 Operation....
-
11B-408.4.1 Car dimensions and doors
Exceptions: Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear...
-
11B-411.1.1 Floor designations
installed or existing elevators are altered into a destination-oriented elevator system, levels within stories, such as mezzanines located above or below the main entry level shall be permitted...
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
11B-408.4.1 Car dimensions and doors
Exceptions: Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear...
-
11B-1009.2.7 Operation
The lift shall be stable and not permit unintended movement when a person is getting into or out of the seat. [2010 ADA Standards] 1009.2.7 Operation....