When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
Search Results "Play Area Ramp"
-
§ 38.95(c)(6)(i) Requirement
-
F234.2 Load and Unload Areas
Load and unload areas serving amusement rides shall comply with 1002.3....
-
234.2 Load and Unload Areas
Load and unload areas serving amusement rides shall comply with 1002.3....
-
DSA Drawing 11B-406-8C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
4.1.1(3) Areas Used Only by Employees as Work Areas
(3)* Areas Used Only by Employees as Work Areas....
-
Q7: Curb Ramp for a Sidewalk that is Not Made of Concrete or Asphalt
Q7: Is a curb ramp required for a sidewalk that is not made of concrete or asphalt?...
-
Width [4.7.3] and Surface [4.7.4]
The minimum clear width of a curb ramp is 36 inches, exclusive of flared sides....
-
11B-215.2 Public and common use areas
Alarms in public use areas and common use areas shall comply with Chapter 9, Section 907.5.2.3.1. [2010 ADAS] 215.2 Public and Common Use Areas. ...
-
11B-215.2 Public and common use areas
Alarms in public use areas and common use areas shall comply with Chapter 9, Section 907.5.2.3.1. [2010 ADAS] 215.2 Public and Common Use Areas. ...
-
11B-215.2 Public and common use areas
Alarms in public use areas and common use areas shall comply with Chapter 9, Section 907.5.2.3.1. [2010 ADA Standards] 215.2 Public and Common Use Areas....
-
T204.2 Doorways with Lifts, Ramps or Bridgeplates
Doorways with lifts or ramps shall comply with T502.2....
-
§ 35.151(g)(2)
(2) Assembly areas that are required to horizontally disperse wheelchair spaces and companion seats by section 221.2.3.1 of the 2010 Standards and have seating encircling, in whole or in...
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.2.2 Height
Each transfer step shall be 8 inches (205 mm) high maximum.
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.1.1 Size
1008.3.1.1 Size. Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
1008.3.2.2 Height
1008.3.2.2 Height. Each transfer step shall be 8 inches (205 mm) high maximum.