Where separate central holding cells are provided for adult male, juvenile male, adult female, or juvenile female, one of each type shall comply with Section 11B-807.2. Where central...
Search Results "Outdoor Constructed Feature"
-
11B-231.3.1 Central holding cells
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-233.3.1.2.6 Public housing facility site impracticality
Communication features complying with Section 11B-809.5.5. 4. Electrical receptacle and switches complying with Section 11B-308.1. 5. ...
-
11B-228.3.2 Minimum number
Note: Electric vehicle charging provided in newly constructed facilities are also subject to the California Green Building Standards Code....
- Increasing Opportunities for Access on the Appalachian Trail: A Design Guide
-
FACTS APPLICABLE TO ALL CLAIMS
Uniform Federal Accessibility Standards ("UFAS"), 1991 ADA Standards for Accessible Design ("ADAAG") or the 2010 ADA Standards for Accessible Design ("2010 ADAAG")), at the time it was constructed...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
15(e)
HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel constructed for first occupancy after the Consent Decree Date has the required number of rooms, as set...
-
§ 35.151(f)(1)
(1) Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping...
-
202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction....
-
4.7.5 Openings
Openings in surface of the clear floor or ground spaces required by section 2.0 shall not allow passage of a sphere more than 1/2 inch (13 mm) in diameter. Where possible, elongated...
-
Surface
The top layer of ground on a recreation site, ORAR, trail, or beach access route.
-
4.4.6 Surface
The surface of the clear floor or ground space for benches shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
3. Discussion of Comments on Related Fair Housing Issues Compliance Deadline
Section 100.205 of the Fair Housing regulations incorporates the Act's design and construction requirements, including the requirement that multifamily dwellings for first occupancy after...
-
202.2 Additions
Each addition to an existing building or facility shall comply with the requirements for new construction....
-
Assistive listening systems. (Section-by-Section Analysis)
Department regulations already require maintenance of accessible features at § 36.211(a) of the title III regulation, which obligates a title III entity to maintain ALS in good working order...