Additionally, the final Guidelines provide that at the primary entry doors to dwelling units with direct exterior access, outside landing surfaces constructed of impervious materials such...
Search Results "Door Clear Width"
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
- Adjusting the Hager Companies 5100 Door Closer
-
Clear Deck Space
Clear Deck Space Clear deck space of 60 by 60 inches minimum, with a slope of not more than 1:48, must be provided at the base of a transfer wall....
-
4.1.3(7)(c)
(c) Each door that is an element of an accessible route shall comply with 4.13....
-
4.1.3(7)(d)
(d) Each door required by 4.3.10, Egress, shall comply with 4.13....
-
Plan 5B: 13-Foot Wide Accessible Guest Room
Features include a transfer shower, comparable vanity, open clothes closet, and door connecting to adjacent guest room. Furnishings include two beds. ...
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum. FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE...
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
305.3 Size
The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. Figure 305.3 Clear Floor or Ground Space...
-
Plan 4A: 13-Foot Wide Accessible Guest Room
Features include a standard roll-in shower with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room....
-
3.3.4 Clear Floor Length
3.3.4 Clear Floor Length The mean value of clear floor length for our study (1250 mm or 49 in.) is above the clear floor length provided in the U.S. standards (1220 mm or 48 in.)....
-
4.1.3(7)(b)
(b) Within a building or facility, at least one door at each accessible space shall comply with 4.13....
-
5. Clear floor space
Clear floor space is needed for a forward approach to the lavatory....
-
309.2 Clear Floor Space
A clear floor or ground space complying with 305 shall be provided....
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
11B-604.8.1.1.1 Maneuvering space with in-swinging door....
-
1011.2 Clear Ground Space
A clear ground space complying with 1011.2 shall be provided at outdoor constructed features....
-
605.3 Clear Floor Space
A clear floor or ground space complying with 305 positioned for forward approach shall be provided....
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is allowed...
-
Can maneuvering for a forward approach be provided when there is space at least 60” deep in front of a door?
Space at least 60” deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike-side clearance is provided; but...