In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
Search Results "Counter Height"
-
11B-804.3 Kitchen work surface
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
WET BAR
[DSA-AC] An area or space with a counter equipped with a sink and running water but without cooking facilities....
-
WET BAR
[DSA-AC] An area or space with a counter equipped with a sink and running water but without cooking facilities....
-
11B-902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
11B-902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
Water Closet Centerline and Seat Height
Water closets are to be located so that the centerline is 16 to 18 inches from the side wall compartment partition (604.2). Water closets can be located so that this dimension is met...
-
4.2.4 Height of Fire-Building Surface
The fire-building surface within a fire ring shall be at least 9 inches (230 mm) above the floor or ground.
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1136A.2 Switch and control heights
Controls or switches intended to be used by the occupant of the room or area to control lighting and receptacle outlets, appliances, alarms or cooling, heating and ventilating...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
- Guardian Barrier-Free Eyewash: Deck Mounted, AutoFlow™ 90º Swing-Down GBF1849
- Pressalit Care VALUE Support Arm Fixed Height Swing Grab Bar
- Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar
-
382.57 What services must carriers provide if their automated kiosks are inaccessible?
., to wheelchair users because of height or reach issues, to visually-impaired passengers because of issues related to visual displays or touch screens), carriers must ensure equal treatment...
-
205 and 309 Operable Parts
Standards, require operable parts on accessible elements, along accessible routes, and in accessible rooms and spaces to comply with the technical requirements for operable parts, including height...
-
Forward Approach: ADA Standard Section 704.2.1.2
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
9.2* POST OFFICE LOBBIES
Clear passageways in front of customer service counters shall be not less than 48 in (1220 mm) clear width to permit maneuvering of a wheelchair....
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
- Boost Your Business - Chapter 10 - Restroom Fixtures
- Figure 302.2 Carpet Pile Height – Drawing from the U.S. Access Board