(1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel or forward...
Search Results "Ceramic Tile Flooring"
-
FIGURE 11A-10A KITCHEN SPECIFICATIONS
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a parallel or...
-
1133A.1 General
) (1) 30" minimum countertop space for sink installation with removable base cabinet and finish flooring beneath the sink; 30" x 48" minimum clear floor space to allow parallel...
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes. The following are the models that can be...
- Armor-Tile Tactile Systems Surface Applied Systems
- Access Board: Toilet Rooms
-
1150A.1 General
Sites where either Test No. 1 or Test No. 3 is used and it is determined that an accessible route to the common (lobby) entrance is not required, at least 20 percent of the ground floor...
-
Conclusion
study found that the majority of participants (5th percentile) could transfer independently to the platform at a height that was within one inch of the mean wheelchair or scooter seat to floor...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator,...
-
7(2)(b)(v)
The top of the fixture rim is a maximum height of 2'10" above the finished floor. If kneespace is provided below the vanity, the bottom of the apron is at least 2'3" above the floor....
- Magnuson Group UMEA Waste Receptacles
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
-
1010.1.4 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door....
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
Rough Form and Foundation Inspection
ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear floor...
-
Rough Form and Foundation Inspection
ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps, landings, curb ramps and clear floor...
-
Technical Memorandum TM 2013-14 Dining Surfaces
Length Clear floor space complying with TAS 305 for a forward approach is required for an accessible dining surface based on TAS 902.2....
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
In order to assess monetized benefits for the requirement covering water closet clearances in single-user toilet rooms with out-swinging doors, a determination needed to be made...
-
3.4.6 Surface
The surface of each viewing area shall be firm and stable. The type of surface should be appropriate to the setting and level of development.