Bus shelters shall be connected by an accessible route complying with 402 to a boarding and alighting area complying with 810.2. Figure 810.3 Bus Shelters...
Search Results "Boarding Ramp"
-
810.3 Bus Shelters
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
integrated into the platform and stretching the full length of the platform (40-inch minimum) for dual ramped entry raised platforms....
-
A5
Is a curb ramp provided between the vehicle pull up area and the access aisle (see above) or the access aisle and the accessible route to the accessible entrance?...
-
11B-810.3 Bus shelters
Bus shelters shall be connected by an accessible route complying with Section 11B-402 to a boarding and alighting area complying with Section 11B-810.2....
-
T302.3 Openings
Ramp and bridgeplate surfaces shall be permitted to have one opening 1½ inches (38 mm) maximum in width and 4½ inches (115 mm) maximum in length to allow the operator to grasp the ramp or...
-
K. SIDEWALKS
The plan and timetable must be approved by the United States and will specify completion of all required curb ramps or other sloped areas that comply with the applicable architectural standards...
-
K. SIDEWALKS
Within three (3) years of the entry of this Consent Decree, the County will provide curb ramps or other sloped areas complying with the applicable architectural standards as permitted by...
-
4.8.6 Cross Slope and Surfaces
The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5....
-
4.8.6 CROSS SLOPE AND SURFACES
The cross slope of ramp surfaces shall be no greater than 1:50. Ramp surfaces shall comply with 4.5....
-
SIDEWALKS
Unless already provided, within three years of the effective date of this Agreement, the City of Waukegan will provide curb ramps or other sloped areas complying with the Standards or UFAS...
-
11B-705.1.1.3 Color and Contrast
Detectable warning surfaces at transit boarding platform edges, bus stops, hazardous vehicular areas, reflecting pools, and track crossings shall comply with Section 11B-705.1.1.3.1....
-
4.1.7(3)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route to an entrance....
-
4.1.7(2)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route at an entrance....
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Alterations/ Historic Preservation
Steeper slopes are allowed for short ramps where a 1:12 slope is not technically feasible....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Q15: Other Requirements Triggered by Road Resurfacing Alterations
Q15: In addition to the obligations triggered by road resurfacing alterations, are there other title II or Section 504 requirements that trigger the obligation to provide curb ramps? ...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....