Where walks or sidewalks are provided, a curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with Section 11B-406 shall connect the walks or sidewalks...
Search Results "Transition Plate"
-
11B-206.2.19 Pedestrian street crossings
-
11B-206.2.19 Pedestrian street crossings
Where walks or sidewalks are provided, a curb ramp, blended transition, or a combination of curb ramps and blended transitions complying with Section 11B-406 shall connect the walks or sidewalks...
-
11B-404.2.9 Door and gate opening force
At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the...
-
11B-404.2.9 Door and gate opening force
At each location where push plates are provided there shall be two push plates; the centerline of one push plate shall be 7 inches (178 mm) minimum and 8 inches (203 mm) maximum above the...
- Collapsible Water Retainer Shower Dam for Shower Threshold
-
11B-406 Curb ramps, blended transitions and islands
Parallel curb ramps and blended transitions, although permitted by 2010 ADAS, are not defined or given special attention....
-
11B-406 Curb ramps, blended transitions and islands
Parallel curb ramps and blended transitions, although permitted by 2010 ADA Standards, are not defined or given special attention....
- Rockwood Manufacturing Company 70REA Push Plate - .050" Thick 3" x 12" Plate
- Rockwood Manufacturing Company 71A Push Plate - .062" Thick 3" X 12" Plate
- Rockwood Manufacturing Company 70A Push Plate - .050" Thick 3" x 12" Plate
-
§ 38.95(c)(4) Ramp barriers
Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
§ 38.125(c)(6)(ii) Exception
Ramps or bridge plates which are attached to, and deployed from, station platforms are permitted in lieu of car devices provided they meet the displacement requirements of paragraph (c)(...
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum.
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope.
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an...
-
T402.8 Running Slope
The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2.
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is...
-
§ 38.83(c)(6) Attachment
(6) Attachment—
-
§ 38.83(c)(5) Slope
Ramps or bridge plates shall have the least slope practicable....
-
Requirements to Remember for: Bus Rapid Transit Systems
[See subsections ...]
-
§ 38.173 Automated guideway transit vehicles and systems
[56 FR 45756, Sept. 6, 1991, as amended at 61 FR 25416, May 21, 1996]
-
§ 38.95(c)(6)(i) Requirement
When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading...
-
Appendix B to Part 37—FTA Regional Offices
Region 1, Federal Transit Administration, Transportation Systems Center, Kendall Square, 55 Broadway, Suite 920, Cambridge, MA 02142 Region 2, Federal Transit Administration, One Bowling...
-
Transition Planning Seminar Handouts and Comments
What can you contribute to the conversation about transition planning?...