Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3.1 reduce that maximum height to 48 inches....
Search Results "Limited Reach"
-
Side reach (Section-by-Section Analysis)
-
Side reach (Section-by-Section Analysis)
Side reach. The 1991 Standards at section 4.2.6 establish a maximum side-reach height of 54 inches. The 2010 Standards at section 308.3 reduce that maximum height to 48 inches....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
4.34.3(2)(b) Reach Depth More Than 10 in
(b) Reach Depth More Than 10 in (255 mm)....
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis)
407.12.3.2 Obstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an obstructed forward reach is provided, the maximum allowable forward reach to an...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis)
407.12.3.1 Unobstructed Forward Reach (Section-by-Section Analysis) This section proposes that, where an unobstructed forward reach is provided, the operable part must be located 48 inches...
- Savaria Orion LU/LA Elevator Video
- Schumacher Elevator Company: Virtual Plant Tour in HD by SAPTV
- Schumacher: Introduction to Schumacher Elevator Company
- Schumacher Elevator Company: 75th Anniversary Celebration Video
-
11B-308.4 Suggested reach ranges for children
These dimensions apply to either forward or side reaches....
-
11B-308.4 Suggested reach ranges for children
These dimensions apply to either forward or side reaches....
-
Maximum side reach ranges. (Section-by-Section Analysis)
Two groups strongly opposed a safe harbor for side reach ranges, one of which estimated that the revised reach range will provide access to an additional half million individuals with disabilities...
-
§ 36.105(d) Substantially limits
(d) Substantially limits—...
-
§ 35.108(d) Substantially limits
(d) Substantially limits—...
-
Limiting Factor
Limiting Factor—An extreme, uncorrectable environmental barrier that makes the trail beyond the barrier unreachable for people with mobility limitations....
-
Obstructed High Reach
The maximum reach of 48” is reduced to 44” when the depth of reach over an obstruction exceeds 20.” Knee and toe space must extend the full depth of reach....
-
Minimum Required Depth: ADA Standard Section 306.2.3
Section 306.2.3 covers the current ADA Standards for the minimum required depth for toe clearance.