Transfer Type Shower Compartments: ADA Standard Section 608.3.1
Section 608.3.1 covers the current ADA Standards for grab bars in transfer type shower compartments.
-
11B-609.2.1 Circular cross section
Grab bars with circular cross sections shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm) minimum...
-
DSA IR 16-12: GRAB BAR DESIGN AND CONNECTIONS: 2019 CBC
DESIGN REQUIREMENT: Grab bars shall be designed to resist a single concentrated load of 250 LBS applied in any direction at any point on the grab bar such as to produce the maximum load...
-
4.21.4 Grab Bars
4.21.4 Grab Bars. ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor....
-
11B-609 GRAB BARS
[See subsections ...]
-
11B-609 Grab bars
[See subsections ...]
- Murdock Manufacturing Grab Bars
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
Grab Bar Height
Commenters pointed out the proposed rule was not clear on whether the height of grab bars was to be measured to the top or to the centerline. Response....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
Rear Grab Bar
The proposed rule specified that the rear grab bar be 24 inches long minimum, centered on the water closet, or at least 36 inches long "where wall space permits" (604.5.2)....
- Just Manufacturing 30" Stainless Steel Grab Bar
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....
-
609.1 General
Grab bars in toilet facilities and bathing facilities shall comply with 609....