608.8 Shower Enclosures. Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
Search Results "Fixed Shower Head"
-
608.8 Shower Enclosures
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
11B-608.5.2 Standard roll-in type shower compartments
(991 mm) to 41 inches (1041 mm) above the shower floor....
-
11B-608.5.2 Standard roll-in type shower compartments
11B-608.5.2 Standard roll-in type shower compartments....
-
Bug fix policies, practices, and procedures
“Bug fix policies, practices, and procedures” means those policies, practices, and/or procedures that H&R Block implements and maintains to resolve errors, flaws, failures, or faults...
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
608.8 Shower Enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. [ECTCR UFAS 4.21.8, 4.34.5.6]...
-
8. Shower Curbs
Are the roll-in showers free of curbs or lips at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments....
-
11B-608.4 Seats
A folding seat shall be provided in roll-in type showers and transfer type shower compartments. Seats shall comply with Section 11B-610. [2010 ADA Standards] 608.4 Seats....
-
11B-608.4 Seats
A folding seat shall be provided in roll-in type showers and transfer type shower compartments. Seats shall comply with Section 11B-610. [2010 ADA Standards] 608.4 Seats....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.1 Transfer Type Shower Compartments
608.5.1 Transfer Type Shower Compartments....
-
607.4.2.3 Head End Wall
607.4.2.3 Head End Wall. A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub. ...
-
4.21.8 Shower Enclosures
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
4.21.8 SHOWER ENCLOSURES
If provided, enclosures for shower stalls shall not obstruct controls or obstruct transfer from wheelchairs onto shower seats....
-
4.21.8 Shower Enclosures
4.21.8 Shower Enclosures. None of the respondents indicated that there were any variations from ADAAG regarding the shower enclosure....
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
III-7.5175 Fixed seating
III−7.5175 Fixed seating (ADAAG §4.1.3(18)). At least five percent of fixed or built-in seating or tables must be accessible....
-
608.3.2 Standard Roll-In Type Shower Compartments
608.3.2 Standard Roll-In Type Shower Compartments....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section....
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section....
-
1.6.10 Fixed Route System.
1.6.10 Fixed Route System....