Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with Section...
Search Results "Fire Extinguisher"
Commonly Searched Documents
-
11B-243.1 General
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
11B-809.5.1 Building fire alarm system
Where a building fire alarm system is provided, the system wiring shall be extended to a point within the residential dwelling unit in the vicinity of the residential dwelling unit smoke...
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
1009.12 Alarms/emergency warning systems/accessibility
Emergency warning systems provided as part of the fire-alarm system and two-way communication systems required by Chapter 10 shall be designed and installed in accordance with NFPA 72 as...
-
§ 36.304(d)(2)(iii)(K)
(K) Shooting facilities with firing positions, sections 243 and 1010....
-
4.2.5 Raised Edge
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves. ...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
Fire rings, grills, fireplaces, and wood stoves shall comply with 1011.5. Advisory 1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves....
-
105.2.5 NFPA, F105.2.5 NFPA
105.2.5 NFPA F105.2.5 NFPA These sections incorporate by reference the NFPA 72 National Fire Alarm Code (1999 and 2002 Editions)....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. [2010 ADA Standards] 215.1 General....
-
907.2 Where required
An approved manual, automatic, or manual and automatic fire alarm system shall be provided in accordance with Sections 907.2.1 through Section 907.2.23....
-
907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....
-
907.2.5 Group H
A manual fire alarm system shall be installed in Group H-5 occupancies and in occupancies used for the manufacture of organic coatings....
-
NFPA
[DSA-AC] The National Fire Protection Association....
-
NFPA
[DSA-AC] The National Fire Protection Association....
-
NFPA
[DSA-AC] The National Fire Protection Association....
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
[2010 ADAS] 105.2.5 NFPA
Copies of the referenced standards may be obtained from the National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02169-7471, (http://www.nfpa.org)....
-
907.2.3 Group E
A manual fire alarm system shall be installed in Group E occupancies....
-
11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS
[See subsections ...]