[DSA-AC] The National Fire Protection Association....
Search Results "Fire Door"
-
NFPA
-
11B-224.1.2 Guest room doors and doorways
[2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10....
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
CHAPTER 9 FIRE PROTECTION SYSTEMS ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted...
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground....
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
11B-605.5.3 Doors
Urinal compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
[F] SECTION 907
FIRE ALARM AND DETECTION SYSTEMS
[F] SECTION 907 FIRE ALARM AND DETECTION SYSTEMS...
-
907.2.6.2.2 Manual fire alarm boxes
Manual fire alarm boxes are not required to be located in accordance with Section 907.3 where the fire alarm boxes are provided at staff-attended locations having direct supervision over...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
Swinging Doors and Gates: ADA Standard Section 404.2.4.1
Section 404.2.4.1 covers the current ADA Standards for maneuvering clearances at swinging doors and gates.
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....
-
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance...
-
Recessed Doors and Gates: ADA Standard Section 404.2.4.3
Section 404.2.4.3 covers the current ADA Standards for maneuvering clearances at recessed doors and gates.
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum....