Section 408.3 covers the current ADA Standards for limited-use/limited-application elevator doors.
Search Results "Fire Door"
Commonly Searched Documents
-
Elevator Doors: ADA Standard Section 408.3
-
Sliding Doors: ADA Standard Section 408.3.1
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator sliding doors.
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
General: ADA Standard Section 702.1
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter...
-
F215 Fire Alarm Systems
[See subsections ...]
-
215 Fire Alarm Systems
[See subsections ...]
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
907.2.8.1 Fire detection system
single-station smoke alarms required by Section 907.2.10 are connected to the emergency electrical system and are annunciated by guestroom at a constantly attended location from which the fire...
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Are fire extinguishers required to comply with the ADA Standards?
In general, elements that are not fixed or built in, including fire extinguishers, are not required to comply with the ADA Standards....
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
Closing Speed: ADA Standard Section 404.2.8
Section 404.2.8 covers the current ADA Standards for the closing speed of doors.
-
11B-408.3.1 Sliding doors
Sliding hoistway and car doors shall comply with Sections 11B-407.3.1 through 11B-407.3.3 and 11B-408.4.1....
-
11B-404.2.8 Closing speed
Door and gate closing speed shall comply with Section 11B-404.2.8....
-
11B-702 FIRE ALARM SYSTEMS
[See subsections ...]
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted. To see the entire...
-
CHAPTER 9 FIRE PROTECTION SYSTEMS
ETA Editor's Note Sections from California Building Code Chapter 9 that are not adopted by Division of the State Architect - Access Compliance (DSA-AC) have been omitted. To...
-
11B-702 Fire alarm systems
[See subsections ...]