The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
Search Results "Door Control"
Commonly Searched Documents
-
4.13.11* DOOR OPENING FORCE
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
§ 38.107(a)(5)
Door latches and hardware shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist....
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush....
-
404.2.4.2 Doorways without Doors or Gates
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors....
-
Automatic Doors and Power Assisted Doors [4.13.12]
Automatic Doors and Power Assisted Doors [4.13.12] Automated doors are classified by industry standards according to the level of force produced by the door opening....
-
404.2.4.2 Doorways without Doors or Gates
Sliding Doors, and Folding Doors....
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
Doors
DOORS 32” clear width 11B-404.2.3 Maneuvering clearances 11B-404.2.4.1 Level...
-
404.2.9 Door and Gate Opening Force
404.2.9 Door and Gate Opening Force. Fire doors shall have a minimum opening force allowable by the appropriate administrative authority....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-409.3.1 Power operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space....
-
A4.17.5 Doors
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
A4.17.5 DOORS
To make it easier for wheelchair users to close toilet stall doors, doors can be provided with closers, spring hinges, or a pull bar mounted on the inside surface of the door near the hinge...
-
Operating Controls
All controls must be operable without pinching, grasping, or twisting the wrist and with no more than 5 pounds of pressure to comply with accessibility guidelines....
-
C. Doors
Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within...
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
-
Is automation of doors required?
Automation of doors is not required by the Standards, but it is highly recommended for entrance doors where the opening force is significant....
-
407.3.5 Door Delay
407.3.5 Door Delay. Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....
-
404.2.9 Door and Gate Opening Force
The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2....