Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
Search Results "Clear Tread Width"
-
404.3.1 Clear Width
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
404.3.1 Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode....
-
Handrails: ADA Standard Section 1009.3.3
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches (965 mm) maximum. EXCEPTIONS: 1....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
- Queue Solutions QueuePro Twin
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
11B-504.7 Wet conditions
Stair treads and landings subject to wet conditions shall be designed to prevent the accumulation of water....
-
Wet Conditions: ADA Standard Section 504.7
Section 504.7 covers the current ADA Standards for wet conditions at stairways.
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
A4.2.1(2) Space Requirements for Use of Walking Aids
Although people who use walking aids can maneuver through clear width openings of 32 in (815 mm), they need 36 in (915 mm) wide passageways and walks for comfortable gaits....
-
4.3.5.1 90-Degree Turn
Figure 4‒4 shows the accommodation model of the minimum clear width required for the 90-degree turn....
-
Clearances [§403.5]
Clearances [§403.5] The minimum 36” continuous clear width of accessible routes can reduce to 32” at points, such as doorways, for a maximum distance of 24”....
-
Minimum Trail Width
Minimum Trail Width. The width of the trail tread and the adjacent usable surface at the narrowest point on a trail. ...
-
504.4 Tread Surface
504.4 Tread Surface. Stair treads shall comply with 302. Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48....
-
504.4 Tread Surface
Stair treads shall comply with 302. Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
504.4 Tread Surface
Stair treads shall comply with 302. Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface....
-
1011.5 Stair treads and risers
...
-
1011.5 Stair treads and risers
...
-
1009.3.2 Stairway width
Stairways shall have a clear width of 48 inches (1219 mm) minimum between handrails....
-
Aisle: ADA Standard Section 904.3.1
Aisles shall comply with 403.