The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505. Advisory 405.9.1 Extended...
Search Results "Burn Protection"
-
405.9.1 Extended Floor or Ground Surface
-
1005.3.2 Extended Ground or Deck Surface
1005.3.2 Extended Ground or Deck Surface. The ground or deck surface shall extend 12 inches (305 mm) minimum beyond the inside face of the railing. Toe clearance shall be provided...
- Nondiscrimination in Health Programs and Activities
-
Accessible Boat Slips
Edge protection is not required, but if provided, it can be 4 inches high maximum and 2 inches deep maximum at the continuous clear openings....
-
11B-1003.3.1 Boat slip clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum. 3....
-
11B-1003.3.1 Boat slip clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
1003.3.1 Boat Slip Clearance
Edge protection shall be permitted at the continuous clear openings, provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum. 3....
-
11B-1003.3.2 Boarding pier clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
1003.3.2 Boarding Pier Clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (100 mm) high maximum and 2 inches (51 mm) wide maximum....
-
11B-1003.3.2 Boarding pier clearances
Edge protection shall be permitted at the continuous clear openings provided that it is 4 inches (102 mm) high maximum and 2 inches (51 mm) wide maximum....
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by...
- Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
Question/Issue: According to the new 2012 NFPA 101 Life Safety Code, Chapter 7, Section 7.2.2.4.4.5 & Exhibit 7.97, the finger clearance at an existing stair handrail...
-
§ 38.83(b)(5) Platform barriers
(5) Platform barriers. The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the lift during its operation....
-
§ 38.125(b)(5) Platform barriers
(5) Platform barriers. The lift platform shall be equipped with barriers to prevent any of the wheels of a wheelchair or mobility aid from rolling off the lift during its operation....
- Figure 1003.3.1 (Exception 1) Clear Pier Space Reduction at Boat Slips – Drawing from the U.S. Access Board
- Figure 1003.3.1 Boat Slip Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.2 Boarding Pier Clearance – Drawing from the U.S. Access Board
- Figure 1003.3.2 (Exception 1) Clear Pier Space Reduction at Boarding Piers – Drawing from the U.S. Access Board
-
1. Width and Depth of Wheelchair Spaces
final rule), it was necessary to restrict the height of this edge protection for platforms using the exception of 32 inches wide to 4 inches....
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see “Referenced Standards” in...
-
Elevated Dune Crossings
An dune crossing that is elevated or has a slope that exceeds 1:20 (5 percent) that is part of a beach access route must have handrails and edge protection (figure 118)....