Systems Where weather alert systems are provided in emergency transportable housing units, this section requires weather alert systems in units with communication features to provide audible...
Search Results "Audible Beaconing"
Commonly Searched Documents
-
809.3.4 Weather Alert Systems
-
A. Fire Alarms
If the building has an audible fire alarm system, do each of the following rooms in the hotel have a visual alarm strobe light mounted on the wall at 80" above the floor to alert deaf persons...
- Honeywell CH Chimes/Strobes
- Honeywell AS/AH - Selectable Output Strobe & Horns
-
4.10.4 Hall Lanterns
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call....
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
11B-407.4.8.2.1 Signal type
Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
- Honeywell SpectrAlert Advance Selectable Output Devices
-
407.4.8.2.1 Signal Type
[ECTCR UFAS 4.10.13] EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with...
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
-
907.5.2.3.3 Group R-2
Such capability shall be permitted to include the potential for future interconnection of the building fire alarm system with the unit smoke alarms, replacement of audible appliances with...
-
407.4.8.2.2 Signal Level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
407.4.8.2.2 Signal Level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
409.1 General
Where provided, status indicators shall be discernible visually and by touch or sound.
-
407.4.8.2.2 Signal Level
407.4.8.2.2 Signal Level. The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
407.6 Status Indicators
Status indicators, including all locking or toggle controls or keys (e.g., Caps Lock and Num Lock keys), shall be discernible visually and by touch or sound.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
[F] 907.5.2.3.4 Group R-2
Such capability shall be permitted to include the potential for future interconnection of the building fire alarm system with the unit smoke alarms, replacement of audible appliances with...
-
[F] 907.5.2.3.3 Group R-2
The replacement of audible appliances with combination audible/visible appliances....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. [2010 ADA Standards] 215.1 General....